1. High Temperature Alarm (E1)
If the cabinet or rail temperature exceeds the setpoint temperature by 18°F (10°C) or
moreformorethanxhours,"E1"isdisplayed.Thedefaultvalueofxis"2"(2hours).
Thevalueofxcanbechangedunder"F3"ontheservicemenu.(0=Nodelay;1=1;2=2;
3=3 hours)
Note:
•Afterthemachinehasbeenturnedoffandthenturnedbackon,thehigh
temperature alarm feature is not active until the area temperature reaches the
lower setpoint temperature differential.
•Thehightemperaturealarmfeatureoperatesevenduringdefrost.
Reset Options
The alarm will automatically reset once the area temperature reaches the lower setpoint
temperature differential.
Possible Causes (forfurtherdetails,see"III.B.ServiceChart")
•Doorsordrawersareopenedfrequentlyorarenotcompletelyclosed.
•Troublewiththecompressororarefrigerantleak.
•Troublewiththecabinetorrailthermistor.
•Liquidlinevalveclosed.
E1 Alarm Timer
over 2 hours
E1 Alarm Timer Reset
E1 Alarm
Timer under
2 hours
Power On
E1 Alarm Temperature 18°F
(10°C) above setpoint temp.
Setpoint Temperature and
Upper Setpoint Differential 0°F (0°C)
Lower Setpoint
Temperature Differential
3.6°F (2°C)
E1
Alarm
Reset
Temperature Display
E1
Blinking
E1 Alarm
Available
E1 Alarm
E1 Alarm not Available until
Lower Setpoint is Achieved