5. Service Menu
Theservicemenu("F0"to"F9")maybeusedtochangesettings,acquirediagnostic
information, and to view alarm history.
Toaccessthe"F0"through"F9"servicemenuselections,youmustrstdisconnectthe
servicejumper(excluding"F5"whichisaccessiblewithorwithouttheservicejumperin
place). The service jumper is located behind the wire cover below the control box and
connects the control board K151 connector terminals 7 and 8 (white) together. When the
servicejumperisinplace,onlythe"F5"selectionisaccessible.Besuretoreconnectthe
service jumper when nished.
a) Service Menu Access
•EnterServiceMenu:Pressandholdthecabinet"SET"buttonandthe"SERVICEUSE
ONLY"buttonfor5seconds."F0"shouldappearinthedisplayscreen.
•Scroll:Usetheupanddownarrowbuttonstoscrollthroughtheservicemenulist,
settings, and data.
•ViewServiceMenuSetting:Pressthecabinet"SET"buttontoviewtheselectedmenu
setting.
•SaveSetting:Pressthecabinet"SET"buttontosavethenewsetting.
•ReturntoServiceMenuList:Pressthecabinet"SET"buttononceagaintoreturntothe
main service menu list.
•ExitServiceMenu:Pressandholdthecabinet"SET"buttonandthe"SERVICE
USEONLY"buttonfor5secondstoexittheservicemenuatanytime.Ifnobuttonis
pressed, the control board will return to the normal temperature display after 1 minute.
"SERVICEUSEONLY"
button used with cabinet
"SET"buttontoenterand
exit the service menu.
"UP"and"DOWN"arrowbuttons
used to change temperature
settings, scroll through the service
menu, and to change menu settings.
"MANUALDEFROST"
button used to initiate
a manual defrost.
"SET"buttonsusedtoviewcurrenttemperaturesettings.
Cabinet"SET"buttonusedwith"SERVICEUSEONLY"
button to enter and exit the service menu.