4. Controls and Adjustments
The cabinet and rail temperatures are updated every 30 seconds. The control board is
supplied with a service jumper on the K151 connector. Only the temperature setpoint
andthetemperaturescale("F5")maybeadjustedwiththisconnectorinplace.Toview
oradjustotherselections,see"II.D.5.ServiceMenu."
a) Switch Settings
Power Switch "OFF": Unit off (both cabinet and rail).
Power Switch "ON": Cabinet temperature is displayed and cabinet cooling begins.
Cabinet fans and perimeter heaters are on and run continuously (except during defrost).
Rail Cooling Switch "OFF": Rail cooling off, cabinet cooling continues.
Rail Cooling Switch "NORMAL: Designed for use when the rail cover is open. Rail
temperature display on and rail cooling begins. The rail fans operate continuously.
Rail Cooling Switch "LOW": Designed for use when the rail cover is closed. Rail
temperature display is on and rail cooling begins. The rail fans operate intermittently
when"F9"isatthefactorydefaultsetting.Foraccessandadjustmentstothe"F9"
setting,see"II.D.5.ServiceMenu."
Note: A Hoshizaki OEM rail cooling switch must be used if replacing the rail cooling
switch.Fordetailssee"IV.M.RailCoolingSwitch."
b) Temperature Display
The temperature display can be changed between Fahrenheit and Celsius. To change
thetemperaturedisplay,pressandholdthecabinet"SET"buttonandthe"SERVICE
USEONLY"buttonfor5seconds."F0"appearsinthedisplayscreen.Presstheup
arrowbuttonuntil"F5"appearsinthedisplayscreen."F5"istheonlyservicemenu
selection accessible with the service jumper in place.
Pressthecabinet"SET"buttontoviewthetemperaturedisplaysetting.Presstheupor
downarrowbuttontoswitchbetweenF°andC°.Pressthecabinet"SET"buttontosave
thenewsetting.Pressthecabinet"SET"buttonandthe"SERVICEUSEONLY"button
for 5 seconds to return to normal temperature display.
"SET"buttonsusedtoviewcurrenttemperaturesettings.
Cabinet"SET"buttonusedwith"SERVICEUSEONLY"
button to enter and exit the service menu.
"SERVICEUSEONLY"
button used with cabinet
"SET"buttontoenterand
exit the service menu.
"UP"and"DOWN"arrowbuttons
used to change temperature
settings, scroll through the service
menu, and to change menu settings.
"MANUALDEFROST"
button used to initiate
a manual defrost.