Hoshizaki KMH-2000SWH/3 User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
17
Fig. 7b
KMH-2000SWH3
KMH-2000SRH3
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
This unit must be connected to a
three-phase power source.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.
208-230/60/3
4A4807-010
JUNCTION BOX
208-230
V
BROWN
BLACK
L1
L3
RED
L2
208-
230V
208-
230V
• On three phase models, the transformer's voltage tap switch must be positioned to match
incoming voltage at startup.
CAUTION! On three phase models, connect the highest incoming voltage supply
("stinger leg") to the red power supply wire (red common wire to the compressor).
The opening for the power supply connection is 7/8" DIA to t a 1/2" trade size conduit.
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 34 35

Comments to this Manuals

No comments