F. Electrical Connection
WARNING
For All Models
1. Electrical connection must be hard-wired and must meet national, state, and
local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, re, or extensive damage
to equipment.
2. This unit requires an independent power supply. See the nameplate for
proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse
can result in a tripped breaker, blown fuses, or damage to existing wiring.
This could lead to heat generation or re.
3. THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit
could result in death or serious injury.
4. Electrical connection must be made in accordance with the instructions on
the "WARNING" tag, provided with the pig tail leads in the junction box. See
Fig. 7a and 7b.
Additional Warnings for Remote Air-Cooled Model
5. THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power
supply and ground wire to the remote condenser unit are supplied from the
icemaker. See "II.G.6. Electrical Connection."
6. To reduce the risk of electric shock, make all remote condenser unit
connections before connecting the icemaker power supply.
7. On remote air-cooled model, the icemaker should have power for a minimum
of 4 hours prior to startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• On single phase models, the white lead must be connected to the neutral conductor of the
power source. CAUTION! Miswiring may result in severe damage to the icemaker.
KMH-2000SWH
KMH-2000SRH
Fig. 7a
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the icemaker. The white lead
must be connected to the neutral
conductor of the power source.
See diagram below.
4A4801-010
208-230/60/1
(3 wire with neutral for 115V)
JUNCTION BOX
208-230
V
BROWN
BLACK
L1
L2
WHITE
N
1
15-
120V