Hoshizaki“A Superior Degreeof Reliability”www.hoshizaki.comModelKML-700MWH-MLow-Profile Modular Crescent CuberHoshizaki America, Inc.Issued: 10-13-200
10F. Water Supply and Drain ConnectionsSee Fig. 4 or 5 WARNING1. Water supply and drain connections must be installed in accordance with applicable in
11Fig. 4KML-700MWH-M Connection to an Open Drain System2. Water-Cooled Condensera) Connection to an Open Drain System• Condenser water supply inlet is
1Condenser Return Line Shut-Off ValveCondenser Return Line Drain ValveIcemakerDrain Outlet 3/4" FPTIcemaker Water Supply Inlet1/" FPTFig.
13G. Final Checklist WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that
14H. Startup WARNING1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty cov
15III. Cleaning and Maintenance WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or m
168) In bad or severe water conditions, clean the oat switch assembly as described below. Otherwise, continue to step 9.a. Remove the 3 screws securi
172. Sanitizing Procedure - Following Cleaning Procedure1) Dilute 1.5 . oz. (37 ml or .5 tbs) of a 5.5% sodium hypochlorite solution (chlorine ble
18C. Preparing the Icemaker for Long StorageCAUTION1. When storing the icemaker for an extended time or in sub-freezing temperatures, follow the instr
193) Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve.4) Attach
IMPORTANTOnly qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be und
0HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A1HL10A
3CONTENTSImportant Safety Information ... 4I. Specicati
4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,
5MOTOR-COMPRESSOR THERMALLY PROTECTED, NOT INTENDED FOR OUTDOOR USE!Hoshizaki America, Inc.Peachtree City, GAwww.hoshizaki.comICE MAKERWITHOUTSTORAGE
6B. Dimensions/Connections1. KML-700MWH-M (water-cooled marine)Unit: in. (mm)
7II. Installation and Operating Instructions WARNING1. This icemaker must be installed in accordance with applicable international, national, state, a
8C. LocationCAUTION1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C)
9E. Electrical Connection WARNING1. Electrical connection must be hard-wired and must meet international, national, state, and local electrical code r