Page view 35
31
[c] KM-201BWH
30sec 30sec 30sec 30sec 30sec
30sec 30sec 30sec 30sec 30sec
HARVEST CYCLE
Thermistor senses 9°C after more than
8 min 30 sec in harvest cycle (Ver 3.1
or later)
HARVEST CYCLE
Thermistor senses 9°C
after 6 min to 8 min 30 sec
in harvest cycle (Ver 3.1 or
later)
6min 3min 30sec 6min 60sec
FREEZE CYCLE
HARVEST CYCLE
(AFTER BIN FULL)
BIN FULLHARVEST CYCLE FREEZE CYCLEFREEZE CYCLE
HARVEST CYCLE
(INCLUDING DRAIN)
DRAIN VALVE
HOT GAS VALVE
WATER VALVE
ON
OFF
OFF
CLEANING VALVE
ON
OFF
FLOAT SWITCH
ON
OFF
BIN CONTROL
SWITCH
ON
OFF
RELAY: X4
(WV)
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
CONTROL BOARD
RELAY: X6
(DV)
RELAY: X1
(COMP)
RELAY: X2
(HV/FM)
ON
RELAY: X3
(PM)
OFF
FAN MOTOR
ON
OFF
ON
Program Ver 2.5
or earlier
(Auxiliary Code:
V-0 or earlier
)
ON
OFF
PUMP MOTOR
Program Ver 3.2
or later
(Auxiliary Code:
V-1 or later
)
POWER SWITCH
ON
HARVEST CYCLEFREEZE CYCLE
HARVEST CYCLE
(INITIAL)
OFF
PART NAME
9°C
5°C
THERMISTOR
COMPRESSOR
ON
OFF
1°C
Max 6 min
5 sec
Max 6 min Max 6 min
10 sec
Max 6 min
15 sec
10 sec
90 sec
Max 6 min
10 sec
10 sec 10 sec
10 sec OFF, 50 sec ON 10 sec OFF, 50 sec ON 10 sec OFF, 50 sec ON
10°C 10°C
10°C
10 sec
10 sec OFF, 50 sec ON
10°C
Max 6 min Max 6 min