Hoshizaki KM-1601SWH/3 User Manual

Browse online or download User Manual for Freezers Hoshizaki KM-1601SWH/3. Hoshizaki KM-1601SWH/3 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Hoshizaki

Hoshizaki “A Superior Degree of Reliability” www.hoshizaki.comModels KM-1601SAH/3KM-1601SWH/3KM-1601SRH/3Stackable Crescent Cuber Hoshizaki America

Page 2 - IMPORTANT

10 HOSHIZAKI ICE MAKER MODEL NUMBER KM-1601SRH3SERIAL NUMBERAC SUPPLY VOLTAGE 208-230/60/3COMPRESSOR 230V 7.9RLA 65.5LRAPUMP 120V 1.2FLA 60WFAN REMOTE

Page 3 - CONTENTS

11B. Dimensions/Connections1. KM-1601SAH/3 (air-cooled)Note: The storage bin opening must match the bottom opening as in the illustration.Units: mm [i

Page 4 - Important Safety Information

12Note: The storage bin opening must match the bottom opening as in the illustration.Units: mm [in.]2. KM-1601SWH/3 (water-cooled)

Page 5

13Note: The storage bin opening must match the bottom opening as in the illustration.3. KM-1601SRH/3 (remote air-cooled)Units: mm [in.]

Page 6

144. URC-21F, URC-22FUnits: mm [in.]1205[47-7/16]112 0[44-1/16]1230[48-7/16]117 8[46-3/8]444[17-1/2]75[2-15/16]380[14-15/16]659[25-15/16]68[2-11/16]39

Page 7

15II. Installation and Operating Instructions WARNING1. This icemaker must be installed in accordance with applicable national, state, and local codes

Page 8

16C. LocationCAUTION1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C

Page 9

176) Install the bin control thermostat as follows: a. Remove the baffle from the storage bin.b. Remove the tie securing the bin control thermostat as

Page 10 - HOSHIZAKI ICE MAKER

187) Replace the panels and baffle in their correct positions (unless you are installing anupper unit).Note: The bin control thermostat must be check

Page 11 - B. Dimensions/Connections

19Thermostat Bulb Attachment Removed from Upper UnitThermostat Extension Bracket (stainless)Thermostat Bulb Attachment of Lower UnitThermostat Capilla

Page 12 - Units: mm [in.]

2IMPORTANTOnly qualied service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be und

Page 13

20F. Electrical Connection WARNINGFor All Models1. Electrical connection must be hard-wired and must meet national, state, and local electrical code r

Page 14 - 4. URC-21F, URC-22F

21Fig. 8bFig. 8aKM-1601SAHKM-1601SWHKM-1601SRHKM-1601SAH3KM-1601SWH3KM-1601SRH3•Onsinglephasemodels,thewhiteleadmustbeconnectedtotheneutr

Page 15 - B. How to Remove Panels

22G. Installation of Remote Condenser Unit WARNING1. Installation of the remote condenser unit must be performed by properly trained and EPA-certied

Page 16 - C. Location

233. Setup1) Secure the legs to the remote condenser unit with the 8 bolts and nuts provided. See Fig. 11.2) The legs have 8 mounting holes. Secure th

Page 17

24d. Tighten the connection with a wrench until it is tight. At this point, the nut has covered most of the threads on the male tting. e. Mark a refe

Page 18 - See Fig. 6

256) Evacuate through the Schrader access ports on the Parker quick connect couplings and charge with R-404A refrigerant vapor to a pressure of 15 to

Page 19

265. Refrigerant Charge (Line Set Exceeding 66 Feet)CAUTIONThe icemaker, line set, and remote condenser unit must contain the same type of refrigerant

Page 20 - F. Electrical Connection

271) Remove the louver panel. See Fig. 15.2) Remove the junction box cover on the remote condenser unit. Remove the fan motor junction box cover on th

Page 21 -  WARNING

28H. Water Supply and Drain Connections See Fig. 17, 18, and 19 WARNING1. Water supply and drain connections must be installed in accordance with a

Page 22

291. Icemaker•Icemakerwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof3/8"nominalID copper water tubing or equivalent

Page 23 - Mounting Holes

3CONTENTSImportant Safety Information ... 4I. Specicati

Page 24

302. Water-Cooled Condensera) Connection to an Open Drain System•Condenserwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof3/8

Page 25 - (POE) OIL

31b) Connection to a Closed Loop System•Condenserwatersupplyinletis1/2"femalepipethread(FPT).Aminimumof3/8"nominalID copper

Page 26

32I. Final Checklist WARNINGCHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that

Page 27

33J. Startup WARNING1. All parts are factory-adjusted. Improper adjustments may adversely affect safety, performance, component life, and warranty cov

Page 28 - See Fig. 17, 18, and 19

34III. Cleaning and MaintenanceThis icemaker must be cleaned and maintained in accordance with the instruction manual and labels provided with the ice

Page 29 - KM-1601SRH/3

351. Cleaning Procedure1)Dilute27.oz.(800ml)ofHoshizaki"ScaleAway"with5gal.(19l)ofwarmwater.2) Remove all ice from the e

Page 30 - KM-16010SWH/3

3621) Remove the front panel and fully open the cleaning valve.22)Movethecontrolswitchtothe"WASH"position.23) Replace the front pane

Page 31 - KM-1601SWH/3

37B. MaintenanceThis icemaker must be maintained individually, referring to the instruction manual and labels provided with the icemaker. WARNING1. On

Page 32 - I. Final Checklist

385) Attach a compressed air or carbon dioxide supply to the icemaker water supply line drain valve.6)Movethecontrolswitchtothe"ICE"

Page 33 - J. Startup

39HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A1GJ10F

Page 34 - III. Cleaning and Maintenance

4Important Safety InformationThroughout this manual, notices appear to bring your attention to situations which could result in death, serious injury,

Page 35

5I. SpecicationsA. Electrical Data1. KM-1601SAH (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER KM-1601SAHSERIAL NUMBERAC SUPPLY VOLTAGE 208-230/60/1 (

Page 36

62. KM-1601SAH3 (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER KM-1601SAH3SERIAL NUMBERAC SUPPLY VOLTAGE 208-230/60/3COMPRESSOR 230V 9.3RLA 75LRAPUMP 1

Page 37 - B. Maintenance

7The rating label and nameplate provide electrical and refrigerant data. The rating label can be seen by removing the front panel. The nameplate is lo

Page 38

84. KM-1601SWH3 (water-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER KM-1601SWH3SERIAL NUMBERAC SUPPLY VOLTAGE 208-230/60/3COMPRESSOR 230V 7.3RLA 65.5LRAPU

Page 39 - HOSHIZAKI AMERICA, INC

9 HOSHIZAKI ICE MAKER MODEL NUMBER KM-1601SRHSERIAL NUMBERAC SUPPLY VOLTAGE 208-230/60/1 (3 WIRE WITH NEUTRAL FOR 115V)COMPRESSOR 230V 12.8RLA 82LRAPU

Comments to this Manuals