Hoshizaki KM-2000SRF3 User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
11
2. CONTROLLER BOARD
[a] SOLID-STATE CONTROL
1) A HOSHIZAKI exclusive solid-state control is employed in KM-2000SWF3,
KM-2000SRF3, KM-2000SWH3, and KM-2000SRH3 Stackable Crescent Cubers.
2) A Printed Circuit Board (hereafter called “Controller Board”) includes a stable and high
quality control system.
3) All models are pretested and factory-adjusted.
[b] CONTROLLER BOARD
CAUTION
1. Fragile, handle very carefully.
2. A controller board contains integrated circuits, which are susceptible to
failure due to static discharge. It is especially important to touch the metal
part of the unit when handling or replacing the board.
3. Do not touch the electronic devices on the board or the back of the board to
prevent damage to the board.
4. Do not change wiring and connections. Do not misconnect K3, K4 and K5,
because the same connector is used for the Thermistor and Float Switch.
K4 is not connected.
5. Always replace the whole board assembly when it goes bad.
6. Do not short out power supply to test for voltage.
KM-2000SWF3 and KM-2000SRF3 use 2A0836-01 HOSHIZAKI-001 (Control Products - 8 Pin)
or
2A1410-01
HOS-001A (Control Products - 10 Pin)
KM-2000SWH3 and KM-2000SRH3 use 2A1410-01
HOS-001A (Control Products - 10 Pin)
Features of Control Products “E” Controller Board
1) Maximum Water Supply Period - 6 minutes
Water Solenoid Valve opening, in the Defrost (Harvest) Cycle, is limited by the defrost
timer. The Water Valve cannot remain open longer than the maximum period. The Wa-
ter Valve can close in less than six minutes if the defrost cycle is completed.
PART NUMBER TYPE
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 55 56

Comments to this Manuals

No comments