39
l) Booster Tank Error (b1)
• If the booster tank error input contacts stay open for more than 2 seconds, "b1" appears in
the display, and the buzzer sounds.
• If the booster tank error input contacts stay closed for more than 2 seconds, the alarm
resets.
Note: The booster tank error input must be connected to indicate this error code.
Booster tank sends error signal.
b 1
Code Error
Item Possible Cause Remedy
Continues.
Operation
Defective. Repair or replace.
Connection Cable
Open circuit. Repair or replace.
Connector not properly
connected.
Reconnect.
Defective. Replace.
Booster Tank
Control Board
Comments to this Manuals